Int 21/AX=5F3Bh

Prev Next Ralf Interrups Categories Contents

------

LAN Manager Enhanced DOS - NetHandleSetInfo

AX = 5F3Bh
BX = handle
CX = handle_info_1 structure length or sizeof DWORD
DI = parameter number to set
0000h all
0001h number of milliseconds
0002h number of characters
DS:DX -> handle_info_1 structure (DI=0000h) (see #01705)
or DWORD (DI=0001h or 0002h)
SI = level of information (0001h)

Return:
CF clear if successful CX = total bytes available CF set if error AX = error code

See Also: AX=5F3Ch

Format of LAN Manager handle_info_1 structure: Offset Size Description (Table 01705) 00h DWORD number of milliseconds which workstation collects data before it sends the data to the named pipe 04h DWORD number of characters which workstation collects before it sends the data to the named pipe

Category: Network - Int 21h - L

------