Int 21/AH=E3h/SF=16h

Prev Next Ralf Interrups Categories Contents

------

Novell NetWare - CONNECTION SERVICES - GET CONNECTION INFORMATION

AH = E3h subfn 16h
DS:SI -> request buffer (see #01917)
ES:DI -> reply buffer (see #01918)

Return:
AL = status 00h successful

Note: This function is supported by Advanced NetWare 1.0+ and Alloy NTNX

See Also: AH=D7h - AH=DCh"NetWare" - AH=E3h/SF=14h

Format of NetWare "Get Connection Information" request buffer: Offset Size Description (Table 01917) 00h WORD 0002h (length of following data) 02h BYTE 16h (subfunction "Get Connection Information") 03h BYTE logical connection number (01h-64h)

Format of NetWare "Get Connection Information" reply buffer: Offset Size Description (Table 01918) 00h WORD (call) 003Eh (length of following results buffer) 02h DWORD (big-endian) object ID for object logged in on the connection 00000000h if no object logged in 06h WORD (big-endian) type of object 08h 48 BYTEs name of object 38h 7 BYTEs login time (see #01919)

Note: Much of the Novell documentation incorrectly states the reply buffer length as 3Fh instead of 40h, which corresponds to a results length of 3Dh (61) bytes instead of the correct 3Eh (62) bytes

Format of NetWare login time: Offset Size Description (Table 01919) 00h BYTE year (80-99 = 1980-1999, 00-79 = 2000-2079) 01h BYTE month (1-12) 02h BYTE day (1-31) 03h BYTE hour (0-23) 04h BYTE minute (0-59) 05h BYTE second (0-59) 06h BYTE day of week (0 = Sunday)

Category: Netware - Int 21h - N

------

Prev Next Ralf Interrups Categories Contents